MS - 96 Seismic Detector

Cias
  • MS96-1
  • Ms96
  • Ms961

MS96 is a traditional seismic detector equipped with a shock and break-in function. It may be connected to any control panel supporting ON/OFF and/or balanced inputs. Output contacts are generated by a photo-coupler circuit, which is known to display no sensitivity to any type of magnetic interference.
• Analisys: Analogic
• Power supply: 13,8 Vdc
• Surface coverage: 30 mq = 6 m
• Frequency bandwidth: 2 KHz – 15 KHz
• Maximum current consumption: 11 mA(35 mA with active Test)
IMQ performance level: 2nd with Ms96/Test optional tester
• Casing protection grade: IP3X
• Operating enviromental conditions: +5 °C / +40 °C
• Output interface type: Photo-coupler contacts (alarm)
• Alarm: Break-in, shock
• Tampering: Anti-removal, anti-opening, high temperature (80°C)
• Maximum sensitivity: 0,1 mG
• S/N (Signal-to-noise ratio): 20 dB minimum
• Internal test : With MS-96/test optional tester
• Dimensions: 184 × 85 × 50 mm